How to install ARIS Web Guiding System

As a real plug and play system, ARIS adapts to any material, requires no calibration and very little set-up time.

First, plug in the sensor to the 12 prong outlet in the back of the machine, using the guide notch that aligns the plug to the outlet.

12-prong outlet web guiding system

Once the sensor is plugged in, tighten the lock collar to hold the sensor cord in place.

Slide the sensor into the sensor guide rail. Make sure the middle of the sensor is aligned with the material’s edge.

sensor rail web guiding system

Once connected to a 24 volt power supply, the user operator interface featuring language independent icons will come on.

user operator interface web guiding system

A green sensor indicator will verify an operable sensor. Above the icons you will see the material edge position indicator, represented by green and red bars. When the material is in correct position, you will see one red bar and one green bar. If it’s incorrectly placed, you will either see no green bar or red bars on both sides of the green.

user operator interface web guiding system

Once the sensor has been aligned with web, secure the sensor using the thumb screws.

When the screen turns on, the automatic/manual icon will indicating the guides last operating condition. A green icon indicates the guide is in automatic operation. A red icon indicates the guide is in manual operation. The operator can change the condition by pressing the icon once.

user operator interface web guiding system

ARIS does most of the work through its automatic option, so press the icon to set to green and let it roll.